NEK606 Fire Resistant Instrumention Cables S13 BU(i) 250V:
S13 BU(i) 250 V Marine Cable
Applications
These cables are fire resistant, flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.
Standards
IEC 60092-376 |
IEC 60092-351 |
IEC 60092-359 |
IEC 60332-1 |
IEC 60332-3-22 |
IEC 60754-1,2 |
IEC 61034-1,2 |
NEK 606:2004 |
Construction
- Conductors : Circular tinned annealed stranded copper wire to IEC 60228 class 2.
- Insulation : Mica tape + Halogen free EPR compound.
- Twinning : Colour coded cores twisted together.
- Individual Shielding : Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.
- Outer Sheath : Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).
Technical Data
Nominal Cross Section Area | mm² | 0.75 | 1 | 1.5 | 2.5 |
Nominal Conductor Diameter | mm | 1.1 | 1.3 | 1.6 | 2 |
Maximum Resistant@20℃ | Ω/km | 26.3 | 19.3 | 12.9 | 8.02 |
Mutual Capacitance | nF/km | 85 | 95 | 100 | 110 |
Nominal Inductance@1KHz | MH/km | 0.731 | 0.691 | 0.673 | 0.629 |
Maximum L/R@1KHz | μH/Ω | 20 | 25 | 35 | 55 |
Operating Voltage | V | 250 | 250 | 250 | 250 |
Mechanical and Thermal Properties
- Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
- Temperature Range : -20℃ ~ +90℃.