Single Core MFX300 Mica Tape Power & Control Cables:
Basic Parameters
Cable Feature:unarmoured fire resistant fire resistant, flame retardant,Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed
Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)
Temperature Range: -30℃ ~ +80℃
Standards
IEC 60092-350/351/353/359, IEC 60331-21, IEC 60332-1, IEC 60332-3-22, IEC 60754-1/2, IEC 61034Construction
Conductors: Class 2 stranded copper conductor. Class 5 stranded conductors can be offered upon request.
Insulation: Mica tape + XLPE.
Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request.